Cables in nuclear, aerospace, defense, and utility systems can remain in service for decades. Replacing them is costly and disruptive. K-NDE by ElastoSure turns inspection signals into clear condition, defect, lifetime, and Replace / Monitor / Continue decisions.

Image by ThisisEngineering

Trusted by Industry, Government & Research Leaders

960px-Logo_of_the_United_States_Space_Force_edited.png
cnpc_logotyp_edited_edited.png
id64HoddYL_1786351252661_edited_edited_e
Sandia_National_Laboratories_logo_edited
250px-Lincoln_Lab_icon_edited_edited.png

What Is Cable Insulation Aging?

Cable insulation aging is driven by thermal oxidation, radiation-induced oxidation, hydrolysis, and mechanical fatigue from thermal cycling and vibration. The rate depends on the insulation polymer type: XLPE, EPR, neoprene, PVC, and silicone all have different aging kinetics.

The critical limitation of stand-alone FDR/TDR instruments is that they output waveforms, not diagnoses. Engineers must interpret reflection features and infer the degradation state, making the process subjective and inconsistent. K-NDE automates this interpretation with physics-based signal-to-degradation mapping.

NRC cable aging regulations (NUREG/CR-7000, 10 CFR 50) require utilities to demonstrate cable operability during extended operation. Historically, this has relied on generic assumptions and testing programs. K-NDE enables quantified, cable-specific RUL assessment from actual in-service inspection data.

ChatGPT Image Sep 10, 2026, 02_59_50 PM.png

How ElastoSure Predicts Cable Insulation Aging

K-NDE

Signal-to-diagnosis engine

K-Fail

Cable end-of-life prediction

K-Load

Multi-stressor cable aging

What You Get From ElastoSure

Output

Defect location (meters)

What It Tells You

Where along the cable the anomaly is, to within 0.5m accuracy

Decision Enabled

Send maintenance crew to the right location -- not the whole cable run

Severity classification

Minor / Moderate / Critical rating with documented physics-based justification

Prioritize which cables require immediate action vs. continued monitoring

Remaining Useful Life (RUL)

Years of remaining serviceable life with 90% confidence interval

Justify continued operation to NRC, FAA, or other regulator with documented confidence level

Replace / Monitor / Continue

Single actionable recommendation per cable, with justification audit trail

Eliminate subjective engineer judgment from cable operability decisions

Combined aging state (K-Load)

Thermal + radiation + moisture combined degradation state for harsh environments

Accurate assessment for cables in nuclear, subsea, or HPHT environments

Who Uses This

Image by Lukáš Lehotský

Nuclear Power

Assess aging cables and support long-term plant reliability.

Explore Nuclear

Image by Horizon flights

Aerospace & Defense

Monitor critical wiring and harnesses before failure occurs.

Explore Aerospace

Image by American Public Power Association

Utilities & Grid

Detect cable degradation across aging power infrastructure.

Explore Utilities

ElastoSure in Action

Case Study

Image by Na Yue

Thermal Cycling Aging

Humidity aging & long-term strength retention K-Load lap shear strength retention at 85% RH over 5 years.

View Case Study 

Image by Rick Rothenberg

Thermal Runaway Propagation

How encapsulant aging affects heat propagation between cells.

View Case Study 

bottom of page